Corner Post Endwall High Cube-Bundle

Product Overview

Corner Post Insert is a 3 part per assembly for the inside corner end wall with Add-On extensions for High Cube Containers. 

End Wall Corner Inserts contains:

    • 8 pcs of custom shaped foam inserts – 45 1/4in long 
    • 4 pcs of custom shaped foam inserts – 12 1/4in long 
    • 4 Metal “M” Angle Inserts – 45 1/4in long x 1 3/4 in wide legs
  • SKU: CON-EWCP-HC
  • SKU: CON-EWCP-ST (Order Standard)

$207.00

Box contains 12 foam inside corner shaped insert and 4 inside metal utility corner attachment studs

Description

BACK ORDER ITEM 

Expected the first week of August to keep working see alternate corner method.

Corner Post Inserts Description

(I-EWCP-HC) is part of a assembly that has material to finish the inside corners of the end wall of a standard shipping container. The corner post  inserts infill the corner’s corrugated voids preventing hidden condensation. The Metal “M” angle provides a solid corner stud for finishes like drywall. 

    1. Eliminates field guess work when insulating a corner post.
    2. Corner Post Insert fits the end wall corrugation.
    3. (3) part fast track application.

(I-EWCP-HC) = 12 pcs foam inserts and 4 metal “M” corner studs, each End Wall Corner section is a 3 part assembly designed to work on the inside corner end wall of a container. 

Corner Post Video

Corner Post Insert Properties

(I-EWCP-AD) = 1 End Wall Corner Inserts – interior application

End Wall corner Inserts or the container’s nose corrugation. One box of Inserts covers the end wall.

Dimension 5 1/4 in × 45 1/4in ×  1 5/8 in
Corner Post Submittal pdf
Coverage per boxed unit One Set of inside corners
One Box – 8 pcs foam inserts  (covers inside corners)
Interior side of exposed foam the end wall  2 in thick
Inside Metal Corner (covers inside corners)
Inside fastening width and length 1 3/4 in x 1 3/4in x 45 1/4in
R-Value ASTM C518 R-4.5 per in
ASTM C578 Type II

 

Closed-Cell, injection-molded EPS 

Canadian Standard CAN/ULC S701 Type 2
Foam Density 1.5 lbs per cubic foot
Interiors
Shipping Containers

 

Features / Benefits

(I-EWCP-AD) = 1 End Wall Corner Inserts – interior application

InSoFast engineered system of continuous insulation perfectly suited for shipping container fabrication for the End Wall inside Corner Inserts

  • Simple to install
    • Why work so hard?
    • Adaptable Attachment
    • No Special Tools Needed
  • Built-in Studs*
    • Engineered Framing Studs for interior inside corners
    • Thermally isolated stud framing 
    • No energy penalty for the studs
    • Adhesive Application no holes
  • Closed-cell high pressure fused EPS Insulation
  • Engineered for inside corners of a Shipping Containers
  • Lives up to its name: In So Fast
Estimating Corner Post Insert

Estimating and ordering is simple add together how many  interior end walls, (the “nose” of the container) your container project needs. It is simple to determine the number of boxes needed, it is 1 box per (the “nose” of the container) .  (I-EWCP-HC) = End Wall Corner Inserts for each container end wall. Don’t overestimate.

    • (I-EWCP-HC) = 1 End Wall Corner Inserts – interior application
Estimating Adhesive

POLYURETHANE CONSTRUCTION ADHESIVE

Buy Shipping Container Insulation Panels in Monroe, NC

Green Guard Certified Adhesive:

In Canada the Glue is LePage PL Premium

Estimating Adhesive Quantity

Estimating the amount of adhesive YOU will use has variables beyond our control like condition of your walls and how accurate are you with a glue gun? The example below is for one side wall of a 20′ standard height shipping container you will need approximately 3 tubes of the adhesive. That is in a perfect world. PL Premium 3x adhesive is applied in a ⅜” bead on the backside of the studs onto the ribbed surfaces.  We realize that a 3/8″ bead of glue is very subjective. It is important that there is enough adhesive to squish the dovetails on the back side of the stud when pressed to the container wall. Adhesive follows the “Goldie Locks rule, too much, too little, and just right To verify that enough adhesive is used, press the panel into place. Pull the panel back and check to see if the adhesive has spread out beyond the full width of the stud. It is normal for the panel to “float out” from the side of the container when it is accommodating irregularities in the container walls. Additional adhesive may be necessary in some areas. If you are doing it just right you can expect that 1 large 28-fl oz tube will cover 18 of our 24″ long studs or enough glue at a 3/8″ bead to cover 36 foot long bead of glue. 

Additionally you will have to estimate for glue around openings like windows and doors.

1 large 28-fl oz. / 828 mL tube = 18 (24″ studs or inserts)

  • CX-LP 46 (46 studs) = 46
  • 46 ÷ 18 = 2 1/2 tubes of the adhesive
  • I-SWI (30) = 1 tube of the adhesive

POLYURETHANE CONSTRUCTION ADHESIVE

Rough estimate for  28 ounce tubes of adhesive required

Container Side Wall  End Wall Ceiling  Total Walls & Ceiling Floors Swing Doors Total Estimate
20′- Standard 2 1/2  6 1/2 13 1 1/2 3 18
20′- High Cube 2 1/2  6 1/2 14 1 1/2 3 19
40′- Standard 6 2 1/2  13 28 3 3 34
40′- High Cube 2 1/2  13 29 3 3 34

Important Notice: Container Surface Temperature Applications

When bonding EPS and XPS foam insulation, use above 40°F (4°C) and avoid cure and surface temperatures above 90°F (32°C). Surfaces must be clean, dry and free of frost, grease, dust and other contaminants. Pre-fit all materials and protect finished surfaces. If using cartridge format, cut nozzle at a 45° angle to desired bead size and puncture inner seal. Be very careful not to allow Loctite® PL® Premium to cure on a finished surface.

Technical Data

Shipping, Purchasing & Returns

Please read all the current Shipping, Purchasing & Returns *

Freight Details / Dimensions Weight
Product Code

Number of Parts

Box Dimension

Cubic Feet Per Box

 Weight Per Box

Length

Width

Height

I-EWCP-AD

End Wall Corner Inserts 12 pcs.

16″ 16″ 49″ 7.26 18 Lbs.

Add R-Value with InSoFast PLUS